Whether you are having issues getting your remote working, need to make a code change to your remote and control panels or are having trouble with the function of your doors or gates, choosing a certified Liftmaster troubleshooting specialist is the best option. Some may try to fix the device and mechanism without any solid knowledge about it. Chamberlain Group (CGI), the corporate parent company to LiftMaster, Chamberlain, Merlin and Grifco, is a global leader in access solutions and products. We design and engineer residential garage door openers, commercial door operators and gate entry systems. Read our story. The third image is the page from the installation manual needed. If you do find a rewire or wire fix is necessary, remember to disconnect power to the garage door opener first.
Page 43: Wiring diagram + diagnostic codes, Wiring diagram diagnostic codes, Gate 1, Gate 2
Advertising
42
TROUBLESHOOTING
» WIRING DIAGRAM + DIAGNOSTIC CODES
To protect against fire and electrocution:
• DISCONNECT power and battery BEFORE installing or servicing operator.
For continued protection against fire:
• Replace ONLY with fuse of same type and rating.
Z22
R91
CLOSE
EDGE
R94
R92
R93
L1
R1
R2
Z1
K5
K2
F3
10 A 32 V
D1 ÿ
OPEN EDGE/
PHO T O
OPEN
PHO T O
CLOSE
PHO T O
J18
R227
R2 ÿ 7
Z2 ÿ
R223
P1
Z9
Z8
F2
F6
D4
D2
R9
C64
JMPR1
R224
U4
P2
J1
J19
SINGLE
BUT T O N
CONTROL
INPUTS
FORCE
BI P A R T
DEL A Y
TIMER T O
CLOSE
MIN MAX OFF MAX OFF MAX
OPEN
SINGLE BUT T O N
RESET
S T O P
SHADOW
S1
INTERRUPT
CHGR
OVLD
COM
COM
COM
FUSE
OPEN
LOOP
INPUTS
POWER
B A T T 1
B A T T 2
F1 20 A 32 V
R35
D9
Z3
Z4
U3
D1
D27
F5
C 1 1
C13
C12
D15
C2 R4
Liftmaster User Manual Error Code 11
R1 ÿ 1
R1 ÿÿ
R9 ÿ
Q9
K1
R196
Q22
D8
K3
K4
D21
D22
C4
ACCESSO R Y
OVLD
D6
Liftmaster Garage Door Error Codes
JMPR2
MOV1
MOV2
DB1
U2
Z12
24 V AC /
INPUT
G A TE 2
MAGLOCK
ALARM
C
C
NC
NO
NO
GRN
WHT
YEL
BLU
RED
BRN
GRN
WHT
YEL
BLU
RED
BRN
F4
10 A 32 V
F7
24V
24V
COM
OVLD
OVLD
SWITCHED
ACCESSO R Y
POWER
TIMER
RUNNING
G A TE 2
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
LEARN
LIMITS
DIAGNOSTIC
Liftmaster Error Code 41
G A TE 1
J4
S A V E
MAGLOCK MODE EDGE PHO T O
OFF
OFF
SINGLE
NO
NO
ON
ON DUAL NC NC
LEARN
XMITTER
S8
1 2 3 4 5
O
N
2
1
ANTENNA
CONNECTION
YELLOW/GREEN
(OR OPTIONAL EARTH GROUND WIRE)
Error Code 4 6 Liftmaster
GROUND
G R N
W H T
YE L
B L U
R E D
B R N
GATE 1
G R N
W H T
YE L
B L U
R E D
B R N
K6
EDGE EDGE
OR
EDGE
EDGE
OR OR
PHO T O
PHO T O
OR OR
OR OR
PHO T O
PHO T O
CPS-LN4
24VDC OUTPUT
SWITCHED OFF
IN LOW POWER MODE
OPEN (EXI T LOOP )
SINGLE BUT T O N
RESET
S T O P
COMMON (+24VDC)
COMMON (+24VDC)
SHADOW LOOP
INTERRUP T LOO P
COMMON (+24VDC)
GATE 2
RED
BLA
CK
RED
BLA
CK
BLUE
YELLO
W
GATE 1
ACCESSORY
POWER
1. ANTENNA INPUT
2. CLOSE EDGE 3. OPEN EDGE/PHOTO EYE 4. OPEN PHOTO EYE 5. CLOSE PHOTO EYE 6. 24VDC ACCESSORY OUTPUT 7. CONTROL INPUTS/EXIT LOOP 8. LOOP INPUTS, SAFETY/SHADOW 9. TRANSFORMER INPUT 10. SECOND - OPERATOR ARM CONNECTION 11. 24VDC ACCESSORY OUTPUT 12. MASTER OPERATOR ARM CONNECTION
13. MAGLOCK/SOLENOID OUTPUT
14. FAULT ALARM OUTPUT 15. BATTERY INPUT #1 16. BATTERY INPUT #2 17. DIP SWITCH, S1 18. LEARN XMITTER 19. MASTER GATE JOG 20. LIMIT SET 21. SECOND GATE JOG 22. SBC (SINGLE BUTTON CONTROL) 23. FORCE SET 24. BIPART DELAY SET 25. TIMER TO CLOSE SET
7
8
15
2
3
4
5
6
1
16
23
24
25
9
21
20
19
10
11
12
18
14
22
13
17
NOTE:Batteries must be connected
to operate.
NOTE:Yellow/green wire must
be disconnected when earth ground rod is installed.
CPS-LN4
CPS-LN4
MAGLOCK
C
NC
NO
MAGLOCK
C
NC
NO
Fault Alarm
Siren (optional)
Flashing Strobe (optional)
Solenoid Lock
(optional)
Maglock
(optional)
(not provided)
(not provided)
Liftmaster Error Code 4 4
WIRING DIAGRAM
DIAGNOSTIC CODES
# OF BLINKS
MEANING
1
No Stop Switch Connected
2
Gate 1 Arm Disengaged
3
Gate 2 Arm Disengaged
4
Both Gate Arms Disengaged
RPM Reversal
# OF BLINKS
MEANING
6
Force Reversal
7
Processor Reset
8
ROM Check Failed
9
RAM Check Failed
10
EEPROM Check Failed - Reset Limits
Advertising